Author(s):
Hasna Mandil, Mohammad Abo Saleh, Muhanad Kaseir
Email(s):
promandil955@gmail.com , dr.salehism1978@alepuniv.edu.sy , muhanadka.ph@gmail.com
DOI:
10.52711/0974-360X.2026.00613
Address:
Hasna Mandil, Mohammad Abo Saleh, Muhanad Kaseir
Department of Chemistry, Faculty of Science, Aleppo University, Aleppo, Syria.
*Corresponding Author
Published In:
Volume - 19,
Issue - 9,
Year - 2026
ABSTRACT:
A novel gold electrode modified with 2-Mercaptobenzothiazol-Nafion was developed for the quantification of Se (IV) using pulse anodic differential voltammetry (DPASVA). Various parameters (such as electrolyte, accumulation time, accumulation voltage, etc.) were established to study their effect on the reduction of Se (IV) on the modified electrode. The concentration of Se (IV) was measured in an aqueous HClO4 (0.4 M) solution at pH 0.40, and it has an accumulation potential of-600mV (compared to Ag/AgCl) and a time required to accumulate for 300 seconds. Under the optimum conditions, a linear calibration graph, Ip=f(CSe4+), was obtained in the concentration ranges of 2×10-9 M (0.1579ng/mL) with relative standard deviations (RSD) 4.4%. The developed method was characterized by good efficiency of Se (IV) accumulation and resistance against interactions of participating substances and metal ions in some foods and pharmaceuticals. Compared with selenium determination results using a 3,3'-diaminobenzidine.4HCl-nafion (GEMDN) electrode, the developed electrode gave 2.5 times better accuracy and sensitivity.
Cite this article:
Hasna Mandil, Mohammad Abo Saleh, Muhanad Kaseir. Differential Pulse Anodic Stripping Voltammetric Analysis of Selenium (IV) at a Gold Electrode Modified with 2-Mercaptobenzothiazole. Research Journal Pharmacy and Technology. 2026;19(9):4395-2. doi: 10.52711/0974-360X.2026.00613
Cite(Electronic):
Hasna Mandil, Mohammad Abo Saleh, Muhanad Kaseir. Differential Pulse Anodic Stripping Voltammetric Analysis of Selenium (IV) at a Gold Electrode Modified with 2-Mercaptobenzothiazole. Research Journal Pharmacy and Technology. 2026;19(9):4395-2. doi: 10.52711/0974-360X.2026.00613 Available on: https://rjptonline.org/AbstractView.aspx?PID=2026-19-9-59
REFERENCES:
1. Thangavel K., Selenium Properties for Anti-Cancer, Research J. Pharm and Tech. 2017; 10(10): 3595–3597.
2. Mahood H E., Abbood B M., Physiological and Histological Study of Preventive effect of Antioxidants,
3. Selenium and Vitamin C with Garlic in Rats treated with Sodium Fluoride, Research J. Pharm and Tech. 2018; 11(3): 941–945.
4. Nallagouni C S R., Karnati P R., Effects of Fluoride on Metabolic enzymes of brain and Gastrocnemius muscle of mice: protective role of selenium and alpha-tocopherol, Research J. Pharm and Tech. 2022; 15(6): 2627–2632.
5. Zam W., Alshahneh M., Hasan A., Methods of Spectroscopy for Selenium Determination: A Review, Research J. Pharm. and Tech. 2019; 12(12): 6149–6152.
6. İnam R., Toprak Ç., Determination of Selenium (IV) Using O-Phenylenediamine by Differential Pulse Polarography/Interference of Metal Ions, Turk J Chem. 2004; 28(3): 299–309.
7. Zhihong L., Wenjian Q., Determination of Trace Selenium in the Human Body by Stripping Voltammetric Method with O-phenylene Diamine in Situ, Acta Universitatis Medicinae Tongji. 1992; 6(21): 382–384.
8. Wang J., Sun C., Adsorption voltammetry of selenium in the presence of phenylenediamine (o-PDA), J. Electroanal Chem. 1990; 291(1-2): 59–66.
9. Ramadan A A., Mandil H., Ozoun A., Determination of Se (IV) by Pulse Anodic Stripping Voltammetry with a Vitamin E – Nafion Modified Gold Electrode, Res J of Aleppo Univ, Syria. 2008; (61): 149–184.
10. Ramadan A A., Mandil H., Ozoun A., Differential pulse anodic stripping voltammetric determination of selenium (IV) with a vitamin E–Nafion modified gold electrode, Asian J Chem. 2011; (23): 843–846.
11. Ramadan A A., Mandil H., Shikh-Debes A A., Differential Pulse Anodic Stripping Voltammetric Determination of Selenium (IV) at a Gold Electrode Modified With 3,3′-Diaminobenzidine.4HCl-Nafion, Int J Pharm Pharm Sci. 2014; (6): 148–153.
12. Ramadan A A., Mandil H., Shikh-Debes A A., Development and Validation of Differential Pulse Anodic Stripping Voltammetric Analysis of Selenium (IV) in bulk and in dosage formulations at a Gold Electrode Multi-Modified with a Mixture of 3,3′-Diaminobenzidine.4HCl and Vitamin E, Int J Pharm Pharm Sci. 2017; 9(7): 97–102.
13. Ramadan A A., Mandil H., Ozoun A., Differential pulse anodic stripping voltammetric determination of selenium (IV) with a methylene blue-nafion modified gold electrode, Asian J Chem. 2012; (24): 391–394.
14. Sneka S., Santhakumar P., Antibacterial Activity of Selenium Nanoparticles extracted from Capparis
15. decidua against Escherichia coli and Lactobacillus Species, Research J. Pharm and Tech. 2021; 14(8): 4452–4454.
16. Saha D., Mridha D., Mondal S., Jana M., Kayal S., Organoselenium as a Cancer Chemopreventive Agent against
17. Carcinogenesis, Research J. Pharm and Tech. 2011; 4(3): 367–368.
18. Madhumitha B., Santhakumar P., Jeevitha M., Rajeshkumar S., Green Synthesis of Selenium Nanoparticle using Capparis decidua fruit extract and its Characterization using Transmission Electron Microscopy and UV- Visible Spectroscopy, Research J. Pharm and Tech. 2021; 14(4): 2129–2132.
19. Alqaraleh S Y., Al-Zereini W A., Mwafi N R., Jaffal S M., Al-Qtaitat A I., The Green Synthesis of Selenium Nanoparticles: A Comprehensive Review on Methodology, Characterization and Biomedical Applications, Research J. Pharm and Tech. 2024; 17(8): 4054–4062.
20. Abdelhamid A M., Ali L S., Fansa H A., Srag El-Din A S G., Microwave-Assisted Synthesis of Selenium Nanoparticles: A Comprehensive Review on Optimizing Parameters for Enhanced Bioavailability and Therapeutic Potential, Research J. Pharm and Tech. 2025; 18(5): 2003–2009.
21. Ramadan A A., Mandil H., Shikh-Debes A A., Differential Pulse Anodic Stripping Voltammetric Analysis of Selenium (IV) at a Gold Electrode Modified with O-Phenylenediamine- Nafion, Research J. Pharm and Tech. 2018; 11(5): 2030–2035.
22. Kamali S R., Tsai C H., Chen C N., Comparison of three digestion methods for determination of selenium in green tea samples using fluorescence spectrometry, IOP Conf. Ser: Earth Environ. Sci. 2016; (712).
23. Holscher H H., - Simplified Statistical Analysis Handbook of Methods, Examples and Taples, 1st Ed. Massachusetts, Cahners Books. 2017.