Author(s): E. Lavanya, Dhanraj Ganapathy, Sherlyn Sheeba

Email(s): sherlynsheeba@gmail.com

DOI: 10.5958/0974-360X.2018.00478.X   

Address: E. Lavanya1, Dhanraj Ganapathy2, Sherlyn Sheeba3
1Undergraduate Student, Saveetha Dental College, Saveetha Institute of Medical and Technical science, Chennai.
2Professor and Head of the Department of Prosthodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical science, Chennai.
3Tutor, Department of General Anatomy, Saveetha Dental College, Saveetha Institute of Medical and Technical Science, Chennai
*Corresponding Author

Published In:   Volume - 11,      Issue - 6,     Year - 2018


ABSTRACT:
BACKGROUND: The most common and adequately used treatment for replacement of missing teeth is removable partial dentures. It is widely used, as it is economical and acceptable modality of treatment.An improper design of removable partial denture will result in the accumulation of food debris and plaque on teeth and gingival margins and can compromise periodontal support. AIM: To assess the periodontal health of the primary abutment teeth supporting temporary partial denture prostheses. METHODOLOGY: Twentypatients who have been wearing removable partial denture reported to Saveetha Dental College, aged 32 -72 years for review were included in the study.Patients wearing temporary partial dentures for more than 2 years, both the genders, patients who are willing to participate the study were the included in the study. Patients wearing over dentures, fixed removable prosthesis and patient wearing removable prosthesis for maxillofacial defects were excluded from the study. The primary abutments supporting the temporary partial dentures with retainers were assessed for periodontal status by estimating loss of attachment (LOA) and gingival recession. Loss of attachment (LOA) and gingival recession was measured using Williams probe and read to nearest millimetres (mm) at four areas (mesiobuccal, distobuccal, mesiolingual,distolingual) for each tooth. RESULT: The mean value of loss of attachment of abutment teeth was found to be 1.98+0.28mm and non-abutment tooth was 1.58+0.34 mm and statistically significant difference was observed between the primary and control abutments (T value =5.55, P value < 0.001)(Table 1),while the mean value of gingival recession of abutment teeth and non-abutment teeth was found to be 1.69+0.47 mm and 1.16+0.24 mm respectively and statistically significant difference was observed between the primary and control abutments (T value =4.67, P value < 0.001) (Table 2).CONCLUSION: The patients receiving removable partial denture should be carefully motivated, educated and instructed to prevent periodontal diseases. With carefully designed prosthetic treatment and adequate maintenance of oral hygiene, little or no damage will be caused to remaining teeth and their periodontal support. Periodic recall for review of dentures helps to avoid compromises in oral health.


Cite this article:
E. Lavanya, Dhanraj Ganapathy, Sherlyn Sheeba. Effect of Removable Partial Denture on Periodontal Health of Abutments. Research J. Pharm. and Tech 2018; 11(6): 2587-2590. doi: 10.5958/0974-360X.2018.00478.X

Cite(Electronic):
E. Lavanya, Dhanraj Ganapathy, Sherlyn Sheeba. Effect of Removable Partial Denture on Periodontal Health of Abutments. Research J. Pharm. and Tech 2018; 11(6): 2587-2590. doi: 10.5958/0974-360X.2018.00478.X   Available on: https://rjptonline.org/AbstractView.aspx?PID=2018-11-6-79


Recomonded Articles:

Research Journal of Pharmacy and Technology (RJPT) is an international, peer-reviewed, multidisciplinary journal.... Read more >>>

RNI: CHHENG00387/33/1/2008-TC                     
DOI: 10.5958/0974-360X 

0.38
2018CiteScore
 
56th percentile
Powered by  Scopus


SCImago Journal & Country Rank


Recent Articles




Tags


Not Available