Computational Analysis of Flow Patterns during Inhalation and Exhalation of Carbon-monoxide
Dr. M.V. Shyla, Dr. H. Girija Bai
Assistant Professor, Department of Mathematics, Sathyabama University, Chennai-600 119, Tamil Nadu, India
*Corresponding Author E-mail: shylamv@yahoo.com, girijanameprakash@gmail.com.
ABSTRACT:
A computational model of human nasal cavity is developed from CT scan using MIMICS software. CFD analysis of flow patterns during inhalation and exhalation of carbon-monoxide is performed using Finite volume method. Detailed velocity profiles, pressure distribution, residual plots and streamline patterns during inhalation and exhalation are presented. The implications for olfaction are visualized.
Key words:
KEYWORDS: CFD, Inhalation, Exhalation, Finite volume method, Carbon-monoxide, Human nasal cavity.
1. INTRODUCTION:
Human nose performs filtering and respiration by providing a passage for the air on its path to the lungs. A small portion of the nose and nasal cavity is further involved in the sense of smell with the help of olfactory organs. When we smell, majority of the fluid flows through the nose for respiration. Even though, only a limited fraction of the inhaled fluid reaches the olfactory region, it is enough to trigger an olfactory response. The techniques in CFD and the developments in medical imaging have provided new possibilities for simulation of anatomically realistic nasal flow. Subramaniam et al. in 1998, Keyhani et al. in 1995 and Elad et al. in 1993 built numerical model of physically correct nasal cavity [1-3]. They did a numerical analysis with laminar and stationary flows. Subramaniam et al in 1998 reported larger portion of the flow in the middle meatus which disagreed with the results of Kelly et al. in 2000 [1,4]. The difference was contributed to the anatomic variations between the models. Airflow patterns on both sides were also not compared. Shyla et al. in 2013 and 2015 did flow analysis inside both sides of human nasal cavity during inhaling [5-6].
This work is extended by analyzing flow of carbon-monoxide inside human nasal cavity during both inhalation and exhalation.
2. MATHEMATICAL MODEL:
Navier Stokes equations for viscous, incompressible fluid flow are given by:
3. BOUNDARY CONDITIONS:
Fluid flows inside the human nasal cavity of healthy subject is simulated by applying constant velocity 5m/s at the inlet (nostril). No slip boundary condition on the velocity is considered on the walls of the cavity. The air pressure at the entrance of the nasal cavity is kept at 101325 Pascal (Pa) at both nostrils with density (ρ = 1.1233 kg/m3) and coefficient of viscosity (µ = 1.75e-05 kg/m-s) for carbon-monoxide (Data taken from Fluent software database).
4. CFD SIMULATION:
The nasal geometry in coronal view is taken and meshed in Gambit software. The left nasal cavity has 12187 nodes and 11442 quadrilateral cells. The right nasal cavity has 10051 nodes and 9334 quadrilateral cells. Inlet, outlet and the wall is defined after which the mesh is exported to fluent software for analysis. A finite volume scheme is employed by the software. The governing differential equations (1 - 3) in the integral form are discretized into control volumes at the outset. Implicit second order scheme is applied. All the elements are later assembled resulting in a large linearized matrix. It is solved iteratively by a segregated solver using SIMPLE algorithm. The solution to the system of equations which govern the iterative process is generated. The solution provides clear and detailed information on velocity magnitude, pressure and streamline pattern. Initially, default values are used and then slightly modified for best convergence rate.
5. RESULTS:
|
Graphs |
Left |
Right |
|
Residual plot |
||
|
Velocity |
||
|
Static Pressure |
Figure 1. Results for the Flow of Carbon-monoxide with Inlet Velocity 5 m/s during Inhaling.
Figure 2a. Velocity Profile for theFlow of Carbon-monoxide during Inhaling and Exhaling .
Figure 3. Pressure Distribution for the Flow of Carbon-monoxide during Inhaling and Exhaling
Figure 4. Streamline Pattern for the Flow of Carbon-monoxide during Inhaling and Exhaling
Flow pattern during inhalation of CO is visualized from Figures (1 to 4). Flow pattern during exhalation of CO is presented in Figures (2 to 4). Different velocity magnitudes are represented by different contours with the lowest value represented by blue and highest value represented by red as seen in Figure 2. The velocity field increases in magnitude at positions further away from the inlet. The flow is very little in the meatuses. Regions near the inferior and middle airway have highest flow during inhalation. From Figure 3, pressure distribution at different points of left and right nasal cavities can be viewed. The convergence of the results correct to 3 decimal places is ensured as depicted in residual plots in Figure 1. During expiration, fluid flows with high velocity from nasopharynx and exits the nostril with no appreciable flow inside the olfactory region. The CFD results obtained are consistent with the experimental results found in the literature (Kelly 2000). The solution is tested and validated by performing grid independence test and with the help of residual plots as seen in Figure 1.
6. CONCLUSION:
Thus in this chapter the flow patterns inside human nasal cavity has been thoroughly investigated. The results clearly depict the fact that only part of the inspired fluid reaches the olfactory region. The nasal structure contributes to this factor. It protects the human health from the risk of inhaled materials to a great extent. This analysis can serve as a useful and powerful tool in preparation of preoperative nasal surgery. Numerical simulation helps us to visualize flow patterns and implications for olfaction. The significance of this study is to carefully observe and analyze the fluid flow through human nasal cavity for designing sensors that can be used for trace detection.
7. ACKNOWLEDGEMENT:
My gratitude to my Ph.D. Supervisor, Dr. K. B. Naidu and my colleague Mr. G. Vasanth Kumar for their valuable suggestions. I’m thankful to the Director, Bharat Scans, Chennai for providing the data for this research work.
8. REFERENCES:
1 Subramaniam. R.P, Richardson. R.B, Morgan. K.T, Kimbell. J.S and Guilmette R.A (1998), “Computational Fluid Dynamics Simulations of Inspiratory Airflow in the Human Nose and Nasopharynx”, Inhal. Toxicol., Vol.10, pp. 91–120.
2 Keyhani. K, Scherer. P.W and Mozell. M.M (1995), “Numerical Simulation of Airflow in the Human Nasal Cavity”, J. Biomech Eng., Vol.117, pp. 429-441.
3 Elad. D, Liebental. R, Wening. B. L and Einav. S (1993), “Analysis of air flow patterns in the human nose”, Med and BiolEng and Comput, Vol.31, pp. 585- 592.
4 Kelly. J.T, Prasad. A.k and Wexler. A.S (2000), “Detailed Flow Patterns in the Nasal Cavity”, J Appl. Physiol., Vol.89, pp. 323-337.
5 Shyla M.V., Naidu K.B., “CFD Analysis of Chemical Transport in Human Nose,” Indian Journal of Computer Science and Engineering, IJCSE, ISBN 0976-5166, vol.4, no.2, pp. 91-94, 2013.
6 Shyla. M.V, Naidu. K.B, Vasanth Kumar G and Geetha Ramesh (2015), “Numerical Analysis of Flow Patterns of Hydrogen-Sulfide inside Nasal Cavity”, Journal of Pure and Applied Microbiology, Vol.9, No.2, pp. 1149-1154.
Received on 21.08.2017 Modified on 01.10.2017
Accepted on 19.11.2017 © RJPT All right reserved
Research J. Pharm. and Tech 2018; 11(2):769-772.
DOI: 10.5958/0974-360X.2018.00145.2