2nd International Conference on Fostering Interdisciplinary Research In Health Sciences (ICFIRHS) 2019 (01-May-2019)        |

Journal :   Research Journal of Pharmacy and Technology

Volume No. :   11

Issue No. :  12

Year :  2018

Pages :   5425-5430

ISSN Print :  0974-3618

ISSN Online :  0974-360X


Registration

Allready Registrered
Click to Login

Validated Stability Indicating RP-HPLC method for estimation of antiviral class of drugs Sofosbuvir and Velpatasvir in combination and its comparison with reported methods



Address:   P. Venkateswara Rao1*, A. Lakshmana Rao2, S.V.U.M. Prasad3
1PhD Research Scholar, JNTUK, Kakinada and Vikas College of Pharmacy, Vissannapeta, Krishna DT, AP, India.
2 V. V. Institute of Pharmaceutical Sciences, Gudlavalleru, AP, India.
3School of Pharmacy, JNTUK, Kakinada, AP, India
*Corresponding Author
DOI No: 10.5958/0974-360X.2018.00990.3

ABSTRACT:
A simple, specific, accurate and stability-indicating reverse phase high performance liquid chromatographic method was developed for simultaneous determination of Sofosbuvir and Velpatasvir, using a BDS C8 (150 x 4.6 mm, 5 mm) column and a mobile phase composed of Buffer (0.1% OPA): Acetonitrile (50:50, v/v).The retention time of Sofosbuvir and Velpatasvir was found to be 2.267 mins and 2.983 mins respectively when compared with the developed methods the retention time was very less. Linearity was established in the range of 100-600 µg/ml and 25-150 µg/ml for Sofosbuvir and Velpatasvir respectively. The percentage recoveries of Sofosbuvir and Velpatasvir were found to be 100.34% and 101.37% respectively. The drugs were subjected to acid, alkali, hydrolysis, oxidation, dry heat, photolytic and UV degradation and showed very less degradation where no method has reported about the degradation data. The developed method can be successfully employed for simultaneous quantitative analysis of Sofosbuvir and Velpatasvir in bulk and formulations.When the validation parameters of the method developed are compared with those of the earlier reported methods. The developed method was found to be superior in the aspects such as retention time, system suitability and the method was more economical when compared to others as the run time is only 5 minutes.
KEYWORDS:
Comparison, Degradation, RP-HPLC, Stability, Sofosbuvir and Velpatasvir.
Cite:
P. Venkateswara Rao, A. Lakshmana Rao, S.V.U.M. Prasad. Validated Stability Indicating RP-HPLC method for estimation of antiviral class of drugs Sofosbuvir and Velpatasvir in combination and its comparison with reported methods. Research J. Pharm. and Tech 2018; 11(12): 5425-5430.
[View HTML]     



Visitor's No. :   544933