List of Refereed Journals published by UGC, New Delhi on 28-03-2017-- AJRC (Sr. No.-1025); AJM (Sr. No.-2497); RJET (Sr. No.-7220); RJPP (Sr. No.- 7232): RJPPD (Sr. No.- 7234); RJPT (Sr. No.-7235) (19-Apr-2017)        | List of Refereed Journals published by UGC, New Delhi on 11-01-2017-- Research Journal of Pharmacy and Technology (Sr. No.-275); Asian Journal of Management (Sr. No.-3986); Asian Journal of Research in Chemistry (Sr. No.-4008); Research Journal of Engineering and Technology (Sr. No.-31787); Research (22-Jan-2017)        |

Journal :   Research Journal of Pharmacy and Technology

Volume No. :   4

Issue No. :  4

Year :  2011

Pages :   606-611

ISSN Print :  0974-3618

ISSN Online :  0974-360X


Registration

Allready Registrered
Click to Login

Stability Indicating HPLC Method for Simultaneous Determination of Glimepride, Pioglitazone Hydrochloride and Metformin Hydrochloride in Pharmaceutical Dosage Form



Address:   Deepa R. Patel1*, Laxmanbhai J. Patel2 and Madhabhai M. Patel1
1Kalol Institute of Pharmacy, B/H Old Janpath Hotel, National Highway, Kalol-382721, India
2Shree S. K. Patel College of pharmaceutical education and research, Ganapat University, Kherva-382711, Gujarat, India
*Corresponding Author
DOI No: Not Available

ABSTRACT:
A simple, specific and accurate stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of Glimepride, Pioglitazone hydrochloride and Metformin hydrochloride. An isocratic RP-HPLC was achieved on younglin HPLC system using Varian C18 (250 ? 4.6 mm i.d, 5 µm particle size) column with the mobile phase containing mixture of methanol: phosphate buffer (pH 4.0, adjusted with glacial acetic acid) (70: 30, v/v). The flow rate was 1.0ml/min and the eluent was monitored at 240nm. The retention times of Glimepride, Pioglitazone hydrochloride and Metformin hydrochloride were found to be 9.95, 7.12 and 2.66 min respectively. Linearity was established for Glimepride, Pioglitazone hydrochloride and Metformin hydrochloride in the range of 2-12 µg/ml, 5-30 µg/ml and 200-1200 µg/ml respectively. The percentage recoveries of Glimepride, Pioglitazone hydrochloride and Metformin hydrochloride were found to be in the range of 99.44±0.32, 99.36±0.16, 99.87%±0.7 and 99.89%±0.15 respectively. All the drugs were subjected to acid, alkali, neutral, oxidation and dry heat degradation. The degradation studies indicated, Glimepride and Pioglitazone hydrochloride showed degradation in acid, alkaline, H 2O2, dry heat and in neutral condition. The degradation products were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of Glimepride, Pioglitazone hydrochloride and Metformin hydrochloride in bulk drugs and formulations.
KEYWORDS:
Glimepride, Pioglitazone hydrochloride, Metformin hydrochloride, Stability indicating method.